cdm "Multiple of Interval" configuration setting

book

Article ID: 193573

calendar_today

Updated On:

Products

NIMSOFT PROBES DX Infrastructure Management

Issue/Introduction

Please clarify what this means and how it is used.

Environment

Release : 20.1

Component : UIM - CDM WITH IOSTAT

Resolution

QoS Interval (Multiple of 'Interval'): specifies the monitoring interval between each sample collection for QoS information. For example, If the interval is set to 5 minutes and number of samples is set to 5, the average CPU utilization for the last 25 minutes is displayed in the QoS message.

Note: If the value is greater than 1, the probe only calculates the average data for CPU monitoring. For disk, memory, and paging QoS messages, the probe generates the QoS messages with the current value. The probe only uses the QoS Interval to reduce the frequency of QoS messages. 

Additional Information

https://techdocs.broadcom.com/content/broadcom/techdocs/us/en/ca-enterprise-software/it-operations-management/ca-unified-infrastructure-management-probes/GA/alphabetical-probe-articles/cdm-cpu-disk-memory-performance-monitoring/cdm-im-configuration.html 

What does Interval, Sample and QoS Interval mean in the CDM configuration window?