Fixed Dispatching Priority (DP) on SYSTEM ACTIVITY screen
search cancel

Fixed Dispatching Priority (DP) on SYSTEM ACTIVITY screen

book

Article ID: 193552

calendar_today

Updated On:

Products

SYSVIEW Performance Management

Issue/Introduction

There is mismatch between the IBM SDSF Display Active (DA) and the SYSVIEW SYSTEM ACTIVITY (ACT) screens when displaying the value of Dispatching Priority (DP) for a job/STC: while SYSVIEW is constantly showing a fixed value of FF, at the same time the dispatching priority correctly gets different values on SDSF DA screen for the same job.

Cause

Customer uses VTAM to access SYSVIEW and MVSDATA-JESNODES Schedule was disabled. 

Resolution

Enable MVSDATA-JESNODES Schedule 

Additional Information

To enable schedule use SCHED command in SYSVIEW, then use ENA command in front of following schedule MVSDATA-JESNODES.
Also, you can check other schedules that can cause similar issues, here is a list of the schedules that need to be checked: 

MVSDATA-JESNODES
MVSDATA-JOBS
MVSDATA-SYSTEM
MVSDATA-WMSYSSUM

More information about MVS DATA COLLECTION can be found by following link below.

MVS Data Collection