We are receiving the following messages in the CCITCPGW STC:
CAS9899E - Sysid Mismatch, expected: CCI200A Found: 200A
What steps need to be taken in order to resolve them?
Release : 15.0
Component : CCS390 - CA COMMON SERVICES FOR Z/OS
The Sysid Mismatch message means the SYSID specified on the NODE statement does NOT match the SYSID passed from the connected system on the handshake.
Correct the NODE statement so that the SYSID of the defined remote system is correct.
Issue the following command to determine CCI SYSID on the system:
F ENF,DISPLAY,SYSID