The Datacom Multi-User (MUF) region fails to start because of the following error messages:
DB01900I - MUF mufname,99,YES DB01909E - * - ASTERISK POINTS NEAR ERROR
DB01911E - PARAMETER HAS INVALID VALUE
The following error is also returned:
DB00216E - ERROR IN SYSIN/SYSIPT DATA.
CA Datacom for z/OS versions 14.0 ,15.0 and 15.1
These messages are returned when the "mufname" specified in the above MUF card is not an asterisk (*) and doesn't match any of the MUF logical names specified in TARGET_MUF_LIST parameter of the DBSYSID macro (DBSIDPR module).
Use * as MUF logical name or change the name in DBSIDPR TARGET_MUF_LIST=(name,...)