IEW2456E 9207 SYMBOL DSNTIAR UNRESOLVED
search cancel

IEW2456E 9207 SYMBOL DSNTIAR UNRESOLVED

book

Article ID: 192961

calendar_today

Updated On:

Products

InterTest - CICS InterTest - Batch

Issue/Introduction

SMP/E APPLY errors - for example:
...
GIM23911E ** LINK-EDIT PROCESSING FOR SYSMOD SO04583 FAILED FOR MODULE IN67RCCI IN LMOD IN67FIDB IN THE CAVHLOAD      
             LIBRARY. THE RETURN CODE (08) EXCEEDED THE ALLOWABLE VALUE. DATE 20.165 - TIME 20:21:20 - SEQUENCE NUMBER
             000024 - SYSPRINT FILE SMP00035.                                                                         
...
IEW2456E 9207 SYMBOL DSNTIAR UNRESOLVED.  MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY.  
...
and if Db2 is not being used. 

Environment

Release : 11.0

Component : CA InterTest for CICS

Resolution

If there is no Db2 being used, the CICS SDFHLOAD can be assigned/defined to the SDSNLOAD DD in SMP/E.
Furthermore in this this case the
...
IEW2456E 9207 SYMBOL DSNTIAR UNRESOLVED. ...
...
error is expected and can be ignored.
In order to proceed the acceptable RC for the IEWL utility in SMP/E must be change. This can be done, for example, by running GIMSMP with:
...
//jobcard...
//DDDEFUPD EXEC PGM=GIMSMP,REGION=0M          
//SMPCSI   DD  DISP=SHR,DSN=your.INTSYM11.CSI
//SMPCNTL  DD  *                               
SET BOUNDARY(GLOBAL).                         
UCLIN .                                       
  REP UTILITY(IEWL) NAME(IEWL) RC(
8).         
ENDUCL.                                       
//                                             
...