CA 1 abend with IEFTMS50 7XX- 04 running the FDR backup
search cancel

CA 1 abend with IEFTMS50 7XX- 04 running the FDR backup

book

Article ID: 192524

calendar_today

Updated On:

Products

CA 1 Tape Management CA 1 Tape Management - Copycat Utility CA 1 Tape Management - Add-On Options

Issue/Introduction

CA 1 got the ABEND with IECTMS50 7XX-04(NS32) when the tape job of the multi-volume multi-files writing to the FILESEQ=256.

IECTMS9 05D3,TEST01,TESTJOB,TAPE1   ,2020/190  ,00256,.CAJ1.C1002400        
IEC705I TAPE ON 05D3,TEST01,SL,COMP,TESTJOB,ABRINCL,TESTJOB.CAJ1.C1002400,MEDIA1
IEC205I TAPE1,TESTJOB,ABRINCL,FILESEQ=256, COMPLETE VOLUME LIST,  010          
DSN=TESTJOB.CAJ1.C1002400,VOLS=TEST00,TEST01
IECTMS3 05D3,TEST01,IS NOT SCRTCH (32)                                          
IEFTMS50 7XX- 04 TESTJOB,ABRINCL ,TAPE1   ,05D3,TEST01,00001,.CAJ2.C1002400 
IEFTMS50 ***** CA 1 ABEND,EX,04 *****                  **       

Why dose the CA 1 abend and how to way to recovery this job?

Environment

Release : 14.0

Component : CA 1 Tape Management

Cause

This is not the CA 1 problem.

The MAXFILE parameter of FDR(Backup soft) reached the upper limit(up to 255).

Resolution

Increased the MAXFILE of FDR.