Getting an Endevor ENBE073E MCF integrity error: defining a System on test LPAR
search cancel

Getting an Endevor ENBE073E MCF integrity error: defining a System on test LPAR

book

Article ID: 192503

calendar_today

Updated On:

Products

Endevor

Issue/Introduction

ENBE073E MCF integrity error: System PBS is defined for Environment PROD Stage 1 but not Stage 2             

Environment

Release : All supported versions

Resolution

The 2 most likely causes:

1)  The name of the MCF files are incorrectly specified in the C1DEFLTS

Verify the names of the MCF files specified in the C1DEFLTS matches the MCF files being used.

2)  The MCF files for the specified Environment are out of sync. One file contains data while the other does not. 

If creating a new test instance of Endevor, delete and define both MCF files for the Environment specified.

If using existing data, re-copy both MCF files for the Environment specified.