CA Jobtrac - After upgrading to z/Os 2.2, Jobtrac abended with S878-10 - no active module found - TRAC200C - S878 ABEND IN GJTRVSCH AT +UNKNOWN  
search cancel

CA Jobtrac - After upgrading to z/Os 2.2, Jobtrac abended with S878-10 - no active module found - TRAC200C - S878 ABEND IN GJTRVSCH AT +UNKNOWN  

book

Article ID: 192417

calendar_today

Updated On:

Products

Jobtrac Automic Automation Intelligence

Issue/Introduction

After z/Os 2.2 upgrade , starting CA Jobtrac produces the following :                                         
SYSTEM COMPLETION CODE=878  REASON CODE=00000010                         
                        
    NO ACTIVE MODULE FOUND                                                
   NAME=UNKNOWN                                                          
                                       
TRAC017S SCHEDULE ALLOCATION ERROR: xxxxxxxx   DD=SYSPRINT, ERROR=970C0000
TRAC200C - S878 ABEND IN GJTRVSCH AT +UNKNOWN                            
                         

Environment

Release : 11.0

Component : JOBTRAC

Resolution

CA Top Secret apars SO05230, SO05724 and SO06140 fix a problem with Top Secret orphaning storage which eventually causes storage in subpool 229 to be used up. This causes S878 abends and other short on storage conditions to occur.

These fixes are hyper fixes so it is highly recommended that they are applied.




Additional Information

Check Subpool 229 usage in the dump.  

IBM APARs OA53954/OA55315/OA53955 applied highlight this problem.