I just upgraded my Datacom/AD software to a new version. How can I confirm that the CA 11 data is able to be accessed now?
Component : Datacom/AD
Component : CA 11
Datacom provides a DBUTLTY function called DBTEST that can issue commands to read the database tables for Workload Automation Restart Option for z/OS Schedulers (called CA 11).
The sample job below will read 5 records from each of the tables in the database, using the same logic paths that would be used by the CA 11 application programs. This function will test several processes:
//JOBCARD
//******************************************************************
//* DBUTLTY DBTEST sample to read 5 records from each table in the *
//* CA 11 database. This job can be used to test connectivity to *
//* the MUF and to test that the MUF can process the tables. *
//******************************************************************
//DBTEST1 EXEC PGM=DBUTLTY,REGION=6M
//STEPLIB DD DISP=SHR,DSN=datacom.CUSLIB
// DD DISP=SHR,DSN=datacom.CAAXLOAD
//SYSOUT DD SYSOUT=*
//SYSPRINT DD SYSOUT=*
//SNAPER DD SYSOUT=*
//SYSUDUMP DD SYSOUT=*
//SYSIN DD *
DBURSTR ABEND=YES,MSTNAM=DBMSTLST,MULTUSE=YES
DBURTBL ACCESS=RAN,DBID=0601,TBLNAM=DSN,UPDATE=NO
DBURTBL ACCESS=RAN,DBID=0601,TBLNAM=PRD,UPDATE=NO
DBURTBL ACCESS=RAN,DBID=0601,TBLNAM=RRN,UPDATE=NO
DBURTBL ACCESS=RAN,DBID=0601,TBLNAM=AUD,UPDATE=NO
DBURTBL ACCESS=RAN,DBID=0601,TBLNAM=HST,UPDATE=NO
DBURTBL ACCESS=RAN,DBID=0601,TBLNAM=JOB,UPDATE=NO
DBURTBL ACCESS=RAN,DBID=0601,TBLNAM=MIS,UPDATE=NO
DBURTBL ACCESS=RAN,DBID=0601,TBLNAM=REA,UPDATE=NO
DBURTBL ACCESS=RAN,DBID=0601,TBLNAM=STP,UPDATE=NO
DBURTBL ACCESS=RAN,DBID=0601,TBLNAM=CSD,UPDATE=NO
DBUREND SYSTEM=OS,USRINFO=DBTEST.4.CA11
DBTEST PGM=DBTSTPR DUMP=P
*---+----1----+----2----+----3----+----4----+----5----+----6----+----7
*CMD TBLKEYNM DBIKEY ELM1
LOCKYDSNDSNKY 1
REDLEDSNDSNKY 1 DSNEL
REDNXDSNDSNKY 1 DSNEL 04
*
LOCKYPRDPRDKN 1
REDLEPRDPRDKN 1 PRDEL
REDNXPRDPRDKN 1 PRDEL 04
*
LOCKYRRNRRNKN 1
REDLERRNRRNKN 1 RRNEL
REDNXRRNRRNKN 1 RRNEL 04
*
LOCKYAUDAUDKT 1
REDLEAUDAUDKT 1 AUDEL
REDNXAUDAUDKT 1 AUDEL 04
*
LOCKYHSTHSTKY 1
REDLEHSTHSTKY 1 HSTEL
REDNXHSTHSTKY 1 HSTEL 04
*
LOCKYJOBJOBKY 1
REDLEJOBJOBKY 1 JOBEL
REDNXJOBJOBKY 1 JOBEL 04
*
LOCKYMISMISKY 1
REDLEMISMISKY 1 MISEL
REDNXMISMISKY 1 MISEL 04
*
LOCKYREAREAKY 1
REDLEREAREAKY 1 REAEL
REDNXREAREAKY 1 REAEL 04
*
LOCKYSTPSTPKY 1
REDLESTPSTPKY 1 STPEL
REDNXSTPSTPKY 1 STPEL 04
*
LOCKYCSDCSDKY 1
REDLECSDCSDKY 1 CSDEL
REDNXCSDCSDKY 1 CSDEL 04
/*
For more information about the DBTEST function, please refer to the Datacom documentation for DBUTLTY.