AMPIA 20.4 HOST MONITOR FAILS TO START
search cancel

AMPIA 20.4 HOST MONITOR FAILS TO START

book

Article ID: 192070

calendar_today

Updated On:

Products

CA Application Performance Management Agent (APM / Wily / Introscope) CA Application Performance Management (APM / Wily / Introscope) INTROSCOPE DX Application Performance Management

Issue/Introduction

 APMPIA 20.4 Host Monitor agent failed to start with error regarding "/lib64/libc.so.6: version `GLIBC_2.14' not found (required by /opt/tools/introscope/apmia/SystemEDGE/bin/sysedge)"

Environment

Release : 11.1.3

Component : APM Agents

Cause

Due to the APMIA 20.4 Host Monitor extension being built on a RHEL version newer than 6.10.

Resolution

 

Provided workaround suggestions ( try an older version of Host Monitor extension)
and EA build of a potential fix that would be included in the upcoming DX APM SaaS 20.6 release.