EXPC akea OC4 in ECDIEXPC when executing EXPC in his CICS TS region

book

Article ID: 191955

calendar_today

Updated On:

Products

CA Explore Performance Management for z/VSE

Issue/Introduction

When executing EXPC I receive the following abends

DFHAP0001 ABEND CODE 0C4/AKEA in module ECDIEXPC at offset X'00000344'
DFHME0116 CICSHDF1                                      
(Module:DFHMEME) CICS symptom string for message DFHAP0001 is  PIDS/564805400 LVLS/411 MS/DFHAP0001 RIDS/DFHSRP PTFS/VSE411 AB/S00C4  
AB/UAKEA RIDS/ECDIEXPC ADRS/00000344.           

Cause

Naming conflict

Environment

z/VSE any level
CICS/TS 1/1 and above
Explore for CICS 7.0
Explore for VSE 7.1

Resolution

Recommend ECTIEXPC instead of ECDIEXPC, for your CICS/TS region.