After applying all GA PTFs, the IPL failed with an abend 0C4 during the SVC installation.
CAS9115I - INPUT: PRODUCT(CA1/MVS) VERSION(L0E0) INIT(L0E0INIT) PARM(SVC=240,I IEA995I SYMPTOM DUMP OUTPUT 859 SYSTEM COMPLETION CODE=0C4 REASON CODE=00000011 TIME=07.31.07 SEQ=00008 CPU=0000 ASID=002A PSW AT TIME OF ERROR 070C0000 8001FF3C ILC 6 INTC 11 ACTIVE MODULE ADDRESS=00000000_0001E000 OFFSET=00001F3C NAME=TMSRIM DATA AT PSW 0001FF36 - 20004123 4000D20B D4092022 AR/GR 0: 00000001/BAE02FB8 1: 00000000/00000009 2: 00000000/3AE02FD4 3: 00000000/0000001C 4: 00000000/BAE02FB8 5: 00000000/007FEE88 6: 00000000/007D9FC8 7: 00000000/00FA4E80 8: 00000000/00020000 9: 00000000/00BD8078 A: 00000000/00B83000 B: 00000000/0001F000 C: 00000000/0001E000 D: 00000000/00022FB8 E: 00000000/8001E7E2 F: 00000001/00000000 END OF SYMPTOM DUMP CAS9140E - INIT ERROR: CA1/MVS VER L0E0, INIT ROUTINE RC=S0C4
Environment
Release : 14.0
Component : CA 1 Tape Management
Resolution
Apply the PTF SO13348.
Additional Information
Circumvention: Remove the PTF SO13233
or Rename the load module TMSLVLST to $MSLVLST for example, refresh LLA and rerun CAS9 with: PRODUCT(CA 1/MVS) VERSION(L0E0) INIT(L0E0INIT) - PARM(SVC=nnn,INIT)