Component : CA ACF2 for z/OS
CEA requires the use of OMVS. Running the ACFRPTOM report showed this entry:
SERVICE USERID GROUP UID GID SAF RC RSN
DATE TIME JOBNAME SOURCE SYSID CPU SECLABEL
.....
initUSP CEA * 0 99999999 0 0 0
mm/dd/yy yy.ddd hh.mm.ss CEA SYS1 xxxx
The group showing the * means that ACF2 was not available to gather the information. ACF2 needs to start before CEA. The recommended procedure is to use CAISECxx for starting ACF2. In that way, security will start before other processes in the IPL.
See "Perform CA ACF2 System Initialization" for more information on using CAISEC00.