Can you have PM retrigger an alarm if you clear it in Spectrum accidentally?
book
Article ID: 191067
calendar_today
Updated On:
Products
CA Infrastructure ManagementCA Performance Management - Usage and AdministrationDX NetOps
Issue/Introduction
Can you have PM retrigger an alarm if you clear it in Spectrum accidentally?
Environment
Release : 3.7
Component : IM Reporting / Admin / Configuration
Resolution
Performance Management events have two states, raised and cleared. These are one time events in that if a raise happens, it will not alter until a clear happens. So to get Spectrum to pick up the raise once again, you would need to artificially have PM clear the event by altering the Threshold Monitoring profile settings so that the rule is no longer true. Once the event is cleared, you can put the logic back and the event will retrigger.
The downside to the above is it will clear ALL current raised events for that rule.