"CHASSIS DOWN" and "BLADE STATUS UNKNOWN" alarms on Cisco 2960x device models in Spectrum
search cancel

"CHASSIS DOWN" and "BLADE STATUS UNKNOWN" alarms on Cisco 2960x device models in Spectrum

book

Article ID: 190935

calendar_today

Updated On:

Products

CA Spectrum

Issue/Introduction

"CHASSIS DOWN" and "BLADE STATUS UNKNOWN" alarms on Cisco 2960x device models in Spectrum although these devices are not chassis devices

Environment

Release : Any

Component : Spectrum Core / SpectroSERVER

Cause

Although these device are not switches, they do support the Entity mib. Spectrum uses the Entity mib for chassis management.

Resolution

To disable the creation of the "CHASSIS DOWN" and "BLADE STATUS UNKNOWN" alarms on Cisco 2960x device model:

1. Log into OneClick as an ADMIN user

2. Find and select the Cisco 2960x device model

3. Click on the Attributes tab

4. Find and select the EnableEntityModuleModeling attribute id 0x12ef5 and set the value to No

5. Right mouse click on the model and select Reconfiguration -> Reconfigure Model

6. Right mouse click on the model and select Reconfiguration -> Rediscover SNMP MIBs

Additional Information

Please reference the "Support for Chassis Devices" section of the documentation for more information.