DMSAR Abended with S0C4-PET203I SYSTEM ABEND(S0C4) REASON(00000011) AT PSW(078D2000 00002600)
book
Article ID: 190914
calendar_today
Updated On:
Products
Disk Backup and Restore - MVSDISK BACKUP AND RESTORE- ADD-ON OPTIODISK BACKUP AND RESTORE
Issue/Introduction
DMSAR abend S0C4 with the following messages: IOS000I 0213,7D,NRF,4F,0600,,**,vvvvvv,DMSAR .00C021443AE6AF203110(B31B14010A004E00)0000(50004FFF)CE1F29210C110300 IOS000I 0213,78,EOD,3F,0E00,,**,vvvvvv,DMSAR .084011363EEE34203020(B31800050A004300)0000(50003FFF)CE1F29210C110300 IEC218I 117-08,IFG0232S,DMSAR,DMSAR,ARCHIVY1,0213,vvvvvv, DMS.ARCHPRIM.DMSC.S2020094.T113956 PET203I SYSTEM ABEND(S0C4) REASON(00000011) AT PSW(078D2000 00002600). PET999I CA DISK WAS PROCESSING DSN=nnnnnn PET999I ON VOLUME=gARCHg
Environment
Release : 12.5
Component : CA Disk Backup and Restore
Cause
Into the DMSAR log, there are the following messages: ADSDM126 3613 ABSOLUTE POINT ERROR. DDNAME=ARCHIVY1 DSN=DMS.CRNT.ARCHPRIM.DMSC.S2020094.T113956 BLKID=003AE7B2 RC=0C-00
ADSDM126 3613 ABSOLUTE POINT REWIND FAILED. DDNAME=ARCHIVY1 DSN=DMS.CRNT.ARCHPRIM.DMSC.S2020094.T113956 RC=0C-00
ADSDM126 3613 ABSOLUTE POINT RETRY FAILED. DDNAME=ARCHIVY1 DSN=DMS.CRNT.ARCHPRIM.DMSC.S2020094.T113956 BLKID=003AE7B2 RC=0C-00