Issue/Introduction

During WA ESP initialization the following messages are received even these products WU, WV or WW are not active and only the LMP code for WT have been used for the WA ESP instance:

CAS9180E - CPU 0FD088 REQUIRES A LMP KEY TO RUN PROD (WU)   
CAS9180E - CPU 0FD088 REQUIRES A LMP KEY TO RUN PROD (WV)   
CAS9180E - CPU 0FD088 REQUIRES A LMP KEY TO RUN PROD (WW) 

Environment

Release : ALL

Component : ESP WORKLOAD AUTOMATION

Resolution

WA ESP 11.4 base installation comes with the FMIDs for these products:

CD7ZB40 /*CA ESP ENCORE                 */
CD70B40 /*CA ESP SERVICE GOVERNOR       */
CD71B40 /*CA ESP HIGH AVAILABILITY      */

But for WA ESP 12.0, FMIDs are:

CD7ZC00 /*CA ESP ENCORE                 */
CD70C00 /*CA ESP SERVICE GOVERNOR       */      
CD71C00 /*CA ESP HIGH AVAILABILITY      */

  1. Run an SMP/E DELFMID job to delete the 3 unwanted FMIDs from WA ESP SMP/E zones
  2. refresh the target libraries
  3. restart WA ESP.

    note: to stop CAS9180E messages without deletion of the FMIDs, is to disable these product options by renaming the following modules from the WA ESP load library:
  • CYBHA000 - High Availability Option, product code WU
  • CYBHP000 - Service Governor option, product code WV
  • CYBRM000,CYBRM003 - Encore, product code WW