CAS9020E - INVALID PARAMETER SPECIFIED PARM(PC=PROD,PCC=DBPCCPR
search cancel

CAS9020E - INVALID PARAMETER SPECIFIED PARM(PC=PROD,PCC=DBPCCPR

book

Article ID: 190788

calendar_today

Updated On:

Products

Common Services COMMON SERVICES FOR Z/OS

Issue/Introduction

Starting CAS9 started task and receiving the following error message:,


 CAS9115I - INPUT: PRODUCT(CADATACOM) VERSION(BD15) INIT(DBCR5PR)   
 LOADLIB(DDB.V                                                      
*CAS9173E - ERRORS DETECTED DURING CAIRIM INITIALIZATION            
 CAS9020E - INVALID PARAMETER SPECIFIED  PARM(PC=PROD,PCC=DBPCCPR   
       )                                                            
 CAS9140E - INIT ERROR: CAIRIM  M            VER CAS9, INIT ROUTINE  RC=0008                                                            
 IEF404I CAS9 - ENDED                                              
 $HASP395 CAS9     ENDED - RC=0008                                  

Environment

Release : 15.0
Component : CCS390 - CA COMMON SERVICES FOR Z/OS

Cause

 CARIMPRM  member contained an erroneous character or missing continuation character

Resolution

Create a new CARIMPRM  member and setup product initialization statements
Point the CAS9 started task to this new member if changing the name of the member


Additional Information

Another possible  cause .. if product initialization statements span over multiple lines , it is necessary to add the '-' (hyphen)  at the end of the first line to ensure a continuation to the next line

Please reference the CCS r15.0 which details any necessary modifications to the CAIRIM Initialization Parameters