The following error is displayed in the user creation interface:
[Profile] FullNameHandler - Failed to parse physical attributes: This method requires the presence of an attribute which was not provided. The attribute is named %NAME_SUFFIX%.
A typo exists in the IM UserDir XML and IME Roles XML files where the attribute is incorrectly referenced as %NAME_SUFFFIX% (with three 'F's) instead of the correct %NAME_SUFFIX%.
To resolve this issue, correct the attribute name in the configuration XML files:
%NAME_SUFFFIX% and replace all occurrences with the correct string: %NAME_SUFFIX%.After completing these steps, the |FULL NAME| logical attribute handler will function without error.
For more information on exporting and importing configuration files, see the if further assistance is required.