Self Health Monitor Menu is missing after upgrade to Spectrum 10.4.1
search cancel

Self Health Monitor Menu is missing after upgrade to Spectrum 10.4.1

book

Article ID: 189647

calendar_today

Updated On:

Products

CA Spectrum

Issue/Introduction

Self Health Monitor Menu is missing after upgrade to Spectrum 10.4.1

Environment

Release : 10.4.1

Component : Spectrum Core / SpectroSERVER

Resolution

This is a known issue that will be fixed in all future releases. As a workaround, the issue can be resolved by completing the following steps:

1. Backup a copy of the <SPECROOT>/tomcat/webapps/spectrum/WEB-INF/topo/config/view-vnmdetails-config.xml file to a safe location.

2. Replace this file with the one attached to this article and rename this file to view-vnmdetails-config.xml

3. Stop and restart both the Tomcat and WebTomcat processes.

Additional Information

This issue is also addressed in the 10.04.01.BMP_10.4.101b patch for Spectrum 10.4.1 and in Spectrum 10.4.2 and above.