Spectrum topology not properly synced
book
Article ID: 189490
calendar_today
Updated On:
Products
DX Operational Intelligence
CA Spectrum
Issue/Introduction
After removing one model from Spectrum and the corresponding connection with Switch, OI did not show the update
Environment
Release : 1.3.2
Component : CA DOI SERVICE ANALYTICS
Spectrum 10.4.2
Cause
Creation is pushed immediately to OI from Spectrum, both for models and links.
Device deletion is pushed immediately as well, but link deletion is synced following full sync configuration rate
Resolution
Update possible in ConnectionConfig.xml from 10.4.2 by changing fullSyncInterval in <TasConfiguration> section
<fullSyncInterval>24</fullSyncInterval> <!-- value in hours -->
Change the value to 1 to set for an hourly update, this is the most frequent setting possible
Additional Information
This configuration is available in Spectrum Data Publisher from version 10.4.2 and higher