The AS400 does not start with the error message in its OS/400 system joblog
search cancel

The AS400 does not start with the error message in its OS/400 system joblog

book

Article ID: 188017

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction


The AS400 does not start with the error message in its OS/400 system joblog.

===========================================================================
    Members for file TMP more than maximum allowed.                           

    Unable to open Log file '/QSYS.LIB/UC4.LIB/TMP.FILE/UCEX_TRC##.MBR'.      

     - Member  >System.cpp#sys::System::exec(const String &):870<        
===========================================================================

Environment

Release : 12.x, 11.x
Component: Release : Automation Engine v12.x , AS400 Agent v12.x

Cause

The issue is that  TMP is created with  limited numbers on members.

Resolution

Execute the command below to make the file members unlimited.

CHGPF FILE(UC4/TMP) MAXMBRS(*NOMAX)