Console not communicating
search cancel

Console not communicating

book

Article ID: 187811

calendar_today

Updated On:

Products

Automation Point

Issue/Introduction

Secondary console is not communicating with the mainframe.
Not all messages are appearing on an z/OS console session. Commands can be issued but not all responses received.
 
 

Environment

Release : 11.5 and 11.6

Component : CA Automation Point

Cause

The master console of this LPAR was full. A display of the consoles showed a very high NBUF value:
 
 
D C                                                                 
CNZ4100I 12.30.13 CONSOLE DISPLAY 014                               
CONSOLES MATCHING COMMAND: D C                                      
MSG:CURR=0    LIM=9999 RPLY:CURR=2    LIM=99    SYS=XE65     PFK=00 
HARDCOPY  LOG=(SYSLOG)          CMDLEVEL=CMDS                       
      ROUT=(ALL)                                                    
GRP900    TYPE=MCS      STATUS=ACT-PROD                             
          DEFINED=(*ALL)                                            
          MATCHED=(*ALL)                                            
   ATTRIBUTES ON XE65                                               
      AUTH=(MASTER)    CMDSYS=N/A          NBUF=6500               
      DEV=0900         LOGON=OPTIONAL      USERID=N/A               
      MFORM=(T,J)      AREA=(Z)            PFKTAB=CONS900           
      USE=FC  DEL=R    RTME=1    RNUM=19   SEG=19    CON=N          
      LEVEL=(ALL)                                                   
      MONITOR=(JOBNAMES,SESS)              INTIDS=N  UNKNIDS=N      
      ROUT=(ALL)                                                    

Resolution

After a command was issued to make the master console roll the messages, the buffer was relieved and the AP console started to receive messages again.
Environmental problem.