CIS COMMON SERVICES FOR Z/OS 90S SERVICES DATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OS COMMON PRODUCT SERVICES COMPONENT Common Services CA ECOMETER SERVER COMPONENT FOC Easytrieve Report Generator for Common Services INFOCAI MAINTENANCE IPC UNICENTER JCLCHECK COMMON COMPONENT LDAP SERVER FOR Z/OS Mainframe VM Product Manager CHORUS SOFTWARE MANAGER CA ON DEMAND PORTAL CA Service Desk Manager - Unified Self Service PAM CLIENT FOR LINUX ON MAINFRAME MAINFRAME CONNECTOR FOR LINUX ON MAINFRAME GRAPHICAL MANAGEMENT INTERFACE WEB ADMINISTRATOR FOR TOP SECRET Xpertware MF - MISC OLD CODES SERVICE ASSURE GENERIC UNISERVICE FOR CICS GENERIC UNISERVICE II Output Management Web Viewer

Issue/Introduction

i updated our CCIClient file to point to our HNB2 Port 1202.  

TCPIP.Server=hnb2
TCPIP.Port=1202
TCPIP.Sysid=TSWWSDOC02
TCPIP.DisableTimeout=0
TCPIP.RecvTimeout=60
TCPIP.SendTimeout=60
TCPIP.WaitTimeout=-1
Need confirmation that there is no other change on the server to point to HNB2 instead of HNB7 as we did before.
Getting a message DRAS Server unavailable for security check function trying to go to test LPAR from Web Viewer, yet there is no activity in the DRAS STC on test LPAR...

Environment

Release : 14.1

Component : CAICCI-MVS

Resolution

Web Viewer server CCIClient.properties file updated to have TCPIP.Sysid= parameter set to a unique, 8 character or less value. WVProfile.properties file on the new 12.1 Web Viewer needed to be updated to reflect the new DRAS on the new LPAR. LICENSE.SystemID= and LICENSE.DRASServer= were changed to point to the appropriate values for the new LPAR and DRAS running there.