EZTC0644E error occurred for the RECORD-COUNT keyword. (CA Easytrieve Report Generator)
search cancel

EZTC0644E error occurred for the RECORD-COUNT keyword. (CA Easytrieve Report Generator)

book

Article ID: 187236

calendar_today

Updated On:

Products

PanAudit Plus Easytrieve Report Generator PAN/SQL Easytrieve Report Generator for Common Services

Issue/Introduction

When a existing program of the Easytrieve was run on a customer Linux system, the following error appeared and the program wasn't able to be compiled. (The existing program was able to run on Unix system.)

RECORD-COUNT
 EZTC0644E >>> $ more qualification required

(This problem can be circumvented if qualification is specified like "file name:RECORD-COUNT". However, the program was able to run on Unix system even though the qualification was not specified in the program.)

Environment

Release : 11.6

Component : CA EASYTRIEVE REPORT GENERATOR FOR FOR LINUX PC

Resolution

The latest patch should be applied to the Easytrieve/Linux and the STRTRQU parameter should be set to control the message that relates to a unqualified field name.
For the STRTRQU parameter:
https://techdocs.broadcom.com/content/broadcom/techdocs/us/en/ca-mainframe-software/devops/ca-easytrieve-report-generator/11-6/configuring/configure-your-system/updating-the-table/compiler-options.html#concept.dita_15ae841e0eee41cb337d44421fe7657c44a1860e_STRICTQUStrictQualifier 

"qualification” is a general topic for all fields. The “File Processing Fields” are listed here:
https://techdocs.broadcom.com/content/broadcom/techdocs/us/en/ca-mainframe-software/devops/ca-easytrieve-report-generator/11-6/getting-started/system-defined-fields/file-processing-fields.html