search cancel

Devices are still created when using the SysOID attribute in a discovery filter to exclude devices from being modeled

book

Article ID: 187215

calendar_today

Updated On:

Products

CA Spectrum CA eHealth

Issue/Introduction

Using the discovery filter with the System Object ID not equal to 1.3.6.1.4.1.29719.99 filter still creates the devices even though the System Object ID matches the filter.

Cause

The SysOID attribute is not included in the $SPECROOT/tomcat/webapps/WEB-INF/adisc/config/attr-config.xml file. 

Environment

Release : 10.3
Release : 10.4
Release : 10.4.1

Component : Spectrum Core / SpectroSERVER

Resolution

The issue can be resolved by editing the
($SPECROOT\tomcat\webapps\spectrum\WEB-INF\adisc\config\attr-config.xml) with the following changes:






0x1053
java.lang.String
CSC_TEXT_STRING



A Spectrum Tomcat restart is required after making the change.

This will included in the attr-config.xml file by default in 10.4.2.