Upgrading or initially installing the Database Management for DB2 for Z/OS toolset to R20.
While running Create Required DB2 Objects step
Job fails with
BPA0037E: LOG SYSTEM ssid FAILED ON SQL ERROR: -0904.
Release : 20.0
Component : General Services for DB2
There was an outstanding utility that was holding PTITSBP2 database which has caused -904 sql error.
Another possible cause during initial install: This same -904 error can be seen if there is a lack of available storage to create the log system objects during the Post Install jobs.
There was an outstanding utility that was holding PTITSBP2 database which had caused -904 sql error.
Cleared the utility and could the run the job.
There is no issue with CA tool.
Additionally, if lack of storage to create log system objects, check messages found in DB2MSTR log to find the error messages, obtain additional storage and redo the Post Install.