book
Article ID: 185796
calendar_today
Updated On:
Issue/Introduction
Jobtrac SAMPJCL jobs that use step DDRTVBAS (PGM=DDRTVCAT) may fail with the following when using Datacom/AD r15:
DDRTVT0003 DATABASE NAME INVALID dbid
Or two messages...
DDRTVT0003 DATABASE NAME INVALID dbid
DDRTVT0018 DATABASE BASIS MODULE NOT FOUND
Environment
Release : 11.0
Component : CA Datacom/AD r15.0
Resolution
Apply the following Datacom 15.0 PTFs...
PTF SO09738 along with its PRE ( SO05130 SO07671 )
***NOTE*** This PTF corrects PE PTF SO08186
***NOTE*** This PTF corrects PE PTF SO07671
NOTE:
You will have to modify any job in the SAMPJCL library with references to the -RTV statement
From...
-RTV BASIS,PBASIS
...to...
-RTV BASIS,PDBID,PBASIS
As always, please contact Broadcom support for Jobtrac Job Management if you have further questions.
Additional Information
For additional information you may reference the following Datacom/AD articles:
Article ID: Datacom/AD 15.0 DDRTVT0003 AXPOR01 AXPOR02
https://ca-broadcomcsm.wolkenservicedesk.com/wolken/esd/knowledgebase_list?articleId=138463Article ID: 12045 "Upgrading Datacom/AD 10.0/11.0/12.0 to 15.0"
https://ca-broadcom.wolkenservicedesk.com/external/article?articleId=12045