I am getting a S0C4 abend reason code 10 in TNSLOAD at offset 4F04 in the MATUNER started task. What could be the cause?
search cancel

I am getting a S0C4 abend reason code 10 in TNSLOAD at offset 4F04 in the MATUNER started task. What could be the cause?

book

Article ID: 18433

calendar_today

Updated On:

Products

Mainframe Application Tuner

Issue/Introduction

Description:

The client is receiving a S0C4 abend after first attaching to DB2 Version 910 after issuing the following Modify Command:

F MATUNER,HARVESTER,START,DSN4,DB2E1

This document provides a possible procedural solution.

Solution:

Load Module TNSLOAD abends with a S0C4 Reason Code 10 at Offset 4F04 in Started Task MATUNER when first attaching to DB2 Version 910 after issuing following Modify Command:


F MATUNER,HARVESTER,START,DSN4,DB2E1
 
STC08785  IEA995I SYMPTOM DUMP OUTPUT  506
          SYSTEM COMPLETION CODE=0C4  REASON CODE=00000010
           TIME=12.52.56  SEQ=00781  CPU=0000  ASID=002E
           PSW AT TIME OF ERROR  070C2000   8000CF04  ILC 4  INTC 10
             ACTIVE LOAD MODULE           ADDRESS=00008000  OFFSET=00004F04 
             NAME=TNSLOAD
             DATA AT PSW  0000CEFE - 1244A784  000F5584  0034A774
             GR 0: 00000000_85998599   1: 00000000_00000000
                2: 00000000_00000006   3: 00000000_0000DBC0
                4: A39699A8_4000001C   5: 00000000_00F86020
                6: 00000000_00F86045   7: 00000000_000B7C10
                8: 00000000_04A88600   9: 00000000_00029000
                A: 00000000_000B7BE8   B: 00000000_0000D198
                C: 00000000_0000A6A8   D: 00000000_00080278
                E: 00000000_0000030B   F: 00000000_00000000e 
           END OF SYMPTOM DUMP

Please verify that in the TUNSSP00 Parm member, DB2HVEXT=YES & DB2HVe EXT=DB2E1.

It could be that these CA MAT R9 S0C4 abends are caused by the DB2 Group moving an already active DB2 Subsystem from one z/OS LPAR to another z/OS LPAR without an IPL. The abends occurred when CA MAT tries to connect to this moved DB2 Subsystem that one is testing with.

If these are not the symptoms, please open a new case through CA Support Online. Please provide CA Support with the S0C4 captured as an SVC dump, the complete MATUNER STC LOG, and please provide your maintenance level (last PTF applied, or run an SMP/E LISTMODS against the CA MAT CSI and send in the complete job output).

Environment

Release:
Component: MATUNE