UIM snmpget probe communication failure for SNMP V3 devices after device side restart
book
Article ID: 184086
calendar_today
Updated On:
Products
NIMSOFT PROBESDX Infrastructure Management
Issue/Introduction
snmpget probe keeps communication failure for SNMP V3 devices after device restart or snmp agent restart.
Cause
Probe's internal thread ran out of its pool.
Environment
Component : UIM - SNMPGET
Resolution
Add the following parameter via probe Raw Configure.
<setup>/max_threads =
Default value for the parameter is 30 If you have much more profiles, probe is always ran out of thread pool. Configure the value greater than number of profiles, it will help stabilize re-establishing communication with SNMP V3 target devices.