Error OSF-0005 - When you lock partition attribute or MVL attribute or attachment attribute
search cancel

Error OSF-0005 - When you lock partition attribute or MVL attribute or attachment attribute

book

Article ID: 18219

calendar_today

Updated On:

Products

Clarity PPM SaaS Clarity PPM On Premise

Issue/Introduction

Description:

When you lock the Partition and/or a MVL attribute and click on the Save Button or Save & Return in an Idea or Project instance, the following error message appears:

OSF-0005: Changes were not saved as at least one attribute is locked. To see the locked attributes, reload the page.

This issue can be replicated in Idea and Project objects.
IMPORTANT: This issue will be replicated only if MVL have data, if is NULL, the issue cannot be replicated.

Steps to Reproduce:

Scenario 1: Partition attribute

  1. Environment without partitions (only system)
  2. Create a custom process (start -- > finish)
  3. Create a system action in start step / lock selected attributes
  4. Add the 'PARTITION' attribute
  5. Validate and activate
  6. Create new idea or go to one already created 
  7. Go to Processes Tab / Run your custom process -Make sure that the process is executed correctly
  8. Go to Properties in your idea, and click on 'Save' or 'Save & Return'

Scenario 2: MVL attribute with some value selected

  1. Create a custom process (start -- > finish)
  2. Create a system action in start step / lock selected attributes
  3. Add a MVL attribute
  4. Validate and activate
  5. Create new idea or go to one already created  
  6. Go to Processes Tab / Run your custom process -Make sure that the process is executed correctly
  7. Go to Properties in your idea, and click on 'Save' or 'Save & Return'

Expected Result: Save without error 

Actual Result: OSF-0005: Changes were not saved as at least one attribute is locked. To see the locked attributes, reload the page 

 

Solution:

WORKAROUND:

Remove the Partition and/or MVL attribute from the "Lock" action in the process.

STATUS/RESOLUTION:

CLRT-73904
Resolved in Clarity 13.3 Generic Patch. Reference TEC605767  
Resolved in CA PPM 14.1   

Environment

Release: ESPCLA99000-13.2-Clarity-Extended Support Plus
Component: