Issue:
CA-11 Datacom/AD users may see the following message in their CA Workload Automation Restart Option for z/OS Schedulers (CA-11) 11.0 at startup:
U11D-0260-3 DATACOM CMD=GSETL RC=03(027) TBL=DSN KEYN=DSNKD KEY=CAL7Y
The RC 03(027) in this case means "invalid key".
Environment:
CA Workload Automation Restart Option for z/OS Schedulers (CA-11) 11.0 Version 11.0
CA Datacom/AD Version 12.0 or 14.0
z/OS
Cause:
CA-11 Version 11.0 PTF RO40993 creates two new DSN keys. In order to fully implement them, the PTF ++HOLD ACTION provides instructions to update and catalog the CA-11 database after the PTF has been SMP/e applied.
If you apply the PTF but do not run the steps (on each CA-11 MUF), the CA-11 startup will issue the message indicating that Datacom Return Code 03(27) "invalid key" occurred.
Resolution:
Follow the instructions in the SMP/e ++HOLD ACTION for PTF RO40993.
Additional Information:
Although the message indicating the new key is not present is informational, plan to take the steps to address this.