Cleared alarms are still showing in Spectrum OneClick
search cancel

Cleared alarms are still showing in Spectrum OneClick

book

Article ID: 17949

calendar_today

Updated On:

Products

Spectrum

Issue/Introduction

You may see alarms still displaying in the OneClick console that have already been cleared and when you try to clear them again you get a message:

This alarm has already been cleared

 

Environment

Release:
Component:

Cause

Alarms may persist in the OneClick console even after the SpectroSERVER has cleared the alarm condition on the models if the OneClick server did not receive or fully process the clear event on its end. When this happens the Alarm remains in OneClick's Alarm Table and visible although the SpectroSERVER correctly has the model in a normal condition.

Resolution

Restarting the OneClick process should ensure the OneClick console is updated correctly and the alarms no longer displayed.