Issue/Introduction

As you troubleshoot issues with Workflow Solution, sometimes is necessary to increase the log levels. 
How do I enable full workflow logging?

Environment

Workflow Solution 8.x

ITMS 8.x

Resolution

The complete documentation can be found here:

Method 1: Enable Debug Logging for Running Processes

To enable the most detailed logging level (Debug) for an application that is currently running on the server:

  1. Click Start > Programs > Symantec > Workflow Designer > Tools > Workflow Explorer.
  2. In Workflow Explorer, click the Current Running Processes tab.
  3. Select the running process you wish to troubleshoot.
  4. Click Configure Logging.
  5. Choose the Debug logging level.
  6. Click OK.

Method 2: Enable Global Logging Capture in a Project

If you are developing a project and want to ensure it captures all reporting and logging data:

  1. In Workflow Designer, open your Workflow project.
  2. In the Workflow Designer tool, click the project name.
  3. Click the Reporting tab.
  4. Click Add Process Component.
  5. Click on the project's primary model.
  6. The Global Logging Capture component is now added to your process page, enabling comprehensive reporting.

Method 3: Enable Process Reporting in Process Manager

To enable reporting messages within the Process Manager portal:

  1. In the Process Manager portal, go to the Admin tab.
  2. Click Portal > Master Settings.
  3. In the Reports Settings section, check Process Reporting Messages.

Method 4: Server-Wide Logging Configuration

You can customize logging levels for the entire Workflow environment using the LogicBase.Control.exe utility:

  1. Navigate to C:\Program Files\Symantec\Workflow\Tools. (or C:\Program Files\Altiris\Workflow\Tools if you are running Workflow Solution on the SMP Server)
  2. Run LogicBase.Control.exe.
  3. Use this tool to adjust individual module logging levels to Debug.

Log File Location: By default, log files are written to text files located at: C:\Program Files\Symantec\Workflow\Logs[ApplicationName]

Warning: