GIM30209E ** APPLY PROCESSING FAILED FOR SYSMOD RO42229. REQUIRED SYSMODS FAILED.

book

Article ID: 17717

calendar_today

Updated On:

Products

CA PanAudit Plus CA Easytrieve Report Generator CA PAN/SQL CA Endevor Software Change Manager (SCM) CA Endevor Software Change Manager - Natural Integration (SCM) CA Endevor Software Change Manager - ECLIPSE Plugin (SCM) CA Endevor Software Change Manager - Enterprise Workbench (SCM)

Issue/Introduction

Description:

When applying RO42229, GIM30209E error occurs.


GIM30209E ** APPLY PROCESSING FAILED FOR SYSMOD RO42229. REQUIRED SYSMODS
FAILED
GIM35965I    SYSTEM HOLD ACTION ORIGINATED BY SYSMOD RO42229 WAS NOT RESOLVED.
GIM35912I    CONDITIONAL REQUISITE SYSMOD RO42230 WAS MISSING.
GIM35912I    CONDITIONAL REQUISITE SYSMOD RO42231 WAS MISSING.

Solution:

RO42229 includes the following HOLD information in the apar:


 COMMENT (
  *******************************************************
  *                        NOTE
  *************************************************************
  * IF INITIALLY RUN, JOB JOB0764L MUST BE RERUN AFTER APPLY. *
  *************************************************************

Please make sure that you have resolved the HOLD information and also please make sure that you receive and apply RO42230/RO42231.

Please note:

RO42229 has a pre-req of RO34536.

Before you apply RO42229, please also make sure that you have received RO42230 and RO42231, the IFREQs for RO42229.

Then when all three have been received, please make sure that at least those three are applied together.

Regarding the HOLD statement for the RO42229 which wants you to read that comment, you may code a BYPASS operand on your APPLY command to install SYSMODS that have the internal hold.

The format of the APPLY statement would be after you include the other apars:


    APPLY SELECT(
                RO42230
                RO42231
                RO42229
                       ) REDO BYPASS(HOLDSYS).

Environment

Release: EDBMSU00200-11.6-Easytrieve-Report Generator-Option for DB2-MSU
Component: