When trying to update a Tenant by running GRLoader, no error or warning message appears, yet the Tenant is not updated.
search cancel

When trying to update a Tenant by running GRLoader, no error or warning message appears, yet the Tenant is not updated.

book

Article ID: 17699

calendar_today

Updated On:

Products

CA IT Asset Manager CA Software Asset Manager (CA SAM) ASSET PORTFOLIO MGMT- SERVER SUPPORT AUTOMATION- SERVER CA Service Desk Manager - Unified Self Service CA Service Desk Manager CA Service Management - Asset Portfolio Management CA Service Management - Service Desk Manager

Issue/Introduction

Description:

Generally if GRLoader fails to update a CI, an error or a warning message will be displayed or written in a log. However, when tried to update only Tenant, no error or warning message is displayed as shown below and it looks the CI is updated successfully.

Results:


                  Read   Skipped   Inserts   Updates    Errors  Warnings
CI                2         0         0         2         0        0
Relation          0         0         0         0         0        0

GRLoader completed.
21:54:08.312 GRLoader ended

Solution:

As stated on the Service Desk Manager CA CMDB r12.9 Technical Reference Guide p.193 - GRLoader and Multi-Tenancy, Tenants can only be assigned during the creation of a CI. So if we would like to change the Tenant after we create the CI, we need to run the command pdm_settenant instead.

It is expected behaviour that the GRLoader does not update the Tenant of the CI. Also, no error or warning message appears if the GRLoader does not update it. This is working by design.

Environment

Release: UAPMAC990JPP-12.9-Asset Portfolio Management-Asset Configuration
Component: