On IBM x3650 server, WinPE 2.1 boot hangs at 100% loaded
search cancel

On IBM x3650 server, WinPE 2.1 boot hangs at 100% loaded

book

Article ID: 176878

calendar_today

Updated On:

Products

Deployment Solution

Issue/Introduction

On IBM x3650 servers,WinPE 2.1 Automation boot hangs at 100% loaded.

Cause

Undefined

Resolution

Enable the Execute Disable Bit under the bios options to resolve this issue.

Boot to F1 BIOS setup and navigate to CPU options as follows:

  1. Click on Advanced Setup.
  2. Click on CPU Options.
  3. Change Execute Disable Bit from Disabled to Enabled.

Execute Disable Bit is a hardware-based security feature that can reduce exposure to viruses and malicious-code attacks and prevent harmful software from executing and propagating on the server or network.


Applies To
WinPE 2.1 x86 (x64 bit does not seem to have this issue)

IBM x3650 and possibly x3550