After upgrading to RU2, booting to Automation works through PXE but not ISO (USB or CD).
ITMS 8.5 RU2
GhConfig64.exe and GhRegEdit64.exe files are missing in the WIM.
When upgrading to 8.5 RU2 the bootwiz does not add in All of the Ghost files into the Automation build.
Workaround: Copy the ghost files (..\Program Files\Altiris\Deployment\Imaging\ghost\x64) into ..\Program Files\Altiris\Deployment\BDC\bootwiz\oem. Then create the Automation Folder Installer or Boot CD.
Released as part of DS 8.5 POST_RU2 v1 (See INFO5407)
Also fixed in 8.5 RU3.