Connection Error after configuring the SEPM Embedded Database connection on the SEDR Appliance
search cancel

Connection Error after configuring the SEPM Embedded Database connection on the SEDR Appliance

book

Article ID: 175127

calendar_today

Updated On:

Products

Endpoint Detection and Response

Issue/Introduction

Symantec Endpoint Detection and Response 4.1 and later provides an updated Log Collector for SEPM embedded database utility. The configuration screen allows for a hostname to be provided.

Cause

The field labeled hostname in fact needs a Fully Qualified Domain Name (FQDN), example: "sepm.corp.mycompany.com"

Resolution

To resolve this issue, re-launch the logcollectorconfig.jar configuration utility located in C:\Program Files (x86)\Symantec\Log Collector\ and either provide an FQDN or leave the field blank and configure the connection using the IP address.