CCI not in systemm - cci not allowed

book

Article ID: 17463

calendar_today

Updated On:

Products

CA CIS CA Common Services for z/OS CA 90s Services CA Database Management Solutions for DB2 for z/OS CA Common Product Services Component CA Common Services CA Datacom/AD CA ecoMeter Server Component FOC CA Easytrieve Report Generator for Common Services CA Infocai Maintenance CA IPC Unicenter CA-JCLCheck Common Component CA Mainframe VM Product Manager CA Chorus Software Manager CA On Demand Portal CA Service Desk Manager - Unified Self Service CA PAM Client for Linux for zSeries CA Mainframe Connector for Linux on System z CA Graphical Management Interface CA Web Administrator for Top Secret CA CA- Xpertware CA Compress Data Compression for MVS CA Compress Data Compression for Fujitsu

Issue/Introduction

Description:

When using the Datacom Server PC client to connect to mainframe using CCIPC, the following message comes up:
CCI not in systemm - cci not allowed

<Please see attached file for image>

Figure 1

Solution:

Please verify that you are using for all components - DBSERVER, CCIPC and application, the same kind of architecture (64-bit or 32-bit).

Usually this problem happens when there is a mixture of such.

For example, if the application is a Microsoft Query in 32-bit, than use for 32-bit CCI CCIPCS32.exe and the 32-bit ODBC Datasource.

For a 64-bit MS Query use 64-bit CCI CCIPCS64.exe and the 64-bit ODBC Datasource.

The 32-bit and 64-bit version for the CCIPC application is stored in the CA Common Services delivered CAW0OPTN data set.

Environment

Release: CA90SV00200-14-Common Services-for z/OS
Component:

Attachments

1558709243785000017463_sktwi1f5rjvs16rek.gif get_app