Reporter reporting PSU error messages in event-logging

book

Article ID: 174015

calendar_today

Updated On:

Products

Reporter-S500 Reporter

Issue/Introduction

Customer is receiving error messages about the PSUs on their appliance failing.

Error messages from the event-logs appears as follows:

Dec 24 22:09:42 rpt_10_2-6-x86_64 BCRep[2404]: ss1970=5a4025a6 ALW.CRIT.PSUMON psumon_output.sh:1, shell,, PSU #1 AC status changed to OFF
Dec 24 22:10:13 rpt_10_2-6-x86_64 BCRep[2520]: ss1970=5a4025c5 ALW.CRIT.PSUMON psumon_output.sh:1, shell,, PSU #1 AC status changed to ON
Dec 25 14:22:51 rpt_10_2-6-x86_64 BCRep[12107]: ss1970=5a4109bb ALW.CRIT.PSUMON psumon_output.sh:1, shell,, PSU #2 AC status changed to OFF
Dec 25 14:23:21 rpt_10_2-6-x86_64 BCRep[12222]: ss1970=5a4109d9 ALW.CRIT.PSUMON psumon_output.sh:1, shell,, PSU #2 AC status changed to ON
Dec 25 16:22:32 rpt_10_2-6-x86_64 BCRep[27954]: ss1970=5a4125c8 ALW.CRIT.PSUMON psumon_output.sh:1, shell,, PSU #2 AC status changed to OFF
Dec 25 16:23:02 rpt_10_2-6-x86_64 BCRep[28070]: ss1970=5a4125e6 ALW.CRIT.PSUMON psumon_output.sh:1, shell,, PSU #2 AC status changed to ON

Cause

This is due to the voltage variance being within such a tight degree of difference that Reporter triggers the smallest degree of change and logs it.    The PSU voltage output with these variances trigger erroneous messages within the event logs.  This has been corrected in Reporter 10.3.x and later systems. 

Environment

This occurs on Reporter 10.2.x appliances.  In 10.3.x this issue is not present.  

Resolution

Symantec is aware of this issue and a current bug is being tracked to correct the specifics of the error reporting for accurate event-log messaging in the case of a true PSU failure. 

Bug# RPT-104

 

Note:  Reporter 10.3.x and later do not have this issue.