“System Settings: Optional subsystem” in the Machines datasource returns an empty value which cannot be evaluated using the current operators.

book

Article ID: 170011

calendar_today

Updated On:

Products

Control Compliance Suite Windows

Issue/Introduction

“System Settings: Optional subsystem” in the Machines datasource returns an 
empty value which cannot be evaluated using the current operators.

Cause

Windows platform schema binary is not able to recognize the special
value “{No Value}”.

Environment

CCS 11.5

Resolution

An update to the code has been made in order to allow evaluation of special

value “{No Value}”.

Fix will be available in SCU 2017-2