Issues Restoring a ProxySG Appliance Configuration via CLI or Blue Coat Director. The following error triggered: % Reserved keyword: CCL names cannot begin with "bluecoat-"

book

Article ID: 169007

calendar_today

Updated On:

Products

Asset Management Solution ProxySG Software - SGOS

Issue/Introduction

When the Administrator restores the archive configuration to a ProxySG appliance either through the CLI or with the assistance of a Blue Coat Director appliance, the following error may be produced - "% Reserved keyword: CCL names cannot begin with "bluecoat-":

Cause

This is a known bug (bug#227634) and has been resolved in SGOS version 6.5.8.5 (or above).

Resolution

An SGOS firmware upgrade is required as a permanent fix. Please upgrade the firmware to SGOS version 6.5.8.5 or later.

Workaround

The workaround is to delete the following from the archive (if it exists) before installing the configuration on the ProxySG:

===================
create ccl bluecoat-appliance
edit ccl bluecoat-appliance ;mode
add BC_Engineering_CA
add ABRCA_root
exit
===================