Trap Name | Defined in MIB | Notes |
ColdStart | SNMPv2-MIB | Generated on agent startup |
LinkUp | IF-MIB | Generated for non-management interfaces only |
LinkDown | IF-MIB | Generated for non-management interfaces only |
AuthenticationFailure | SNMPv2-MIB | Generated when there is a snmp authentication failure |
Trap Name | Status Code (sent with the trap) | Other MIB values sent with the trap | Defined in MIB | Notes |
appLicenseStateTrap | Active=1 Expired=2 | ComponentName ExpireType ExpireDate | BLUECOAT-LICENSE-MIB | |
segmentStateTrap | OK = 1 Failure = bitmap of SoftwareFailure | ManualFailure | LinkFailure | ActivationFailure | Identifier Mode IfList IfDownList IfCopyList | BLUECOAT-SEGMENT-MIB | Change of specific ‘Failure’ value is treated as status change and therefore will trigger a Segment Status Change trap. |
deviceSensorTrap (Power Supply, not available on SV800) | OK=1 NoPower = 6 (NotPowered or PowerFailure) NotInstalled = 3 | SensorName | BLUECOAT-SG-SENSOR-MIB | WebUI is able to distinguish between ‘not powered’ and ‘power failure’ as different status. However the Bluecoat Sensor MIB does not define ‘power failure’ status code, therefore SNMP trap is not able to report ‘power failure’ as separate status. |
deviceSensorTrap (Fan) | OK = 1 Warning = 13 Critical = 14 | SensorName SensorValue | BLUECOAT-SG-SENSOR-MIB | Not all platform fan sensors report ‘Warning’ status. Thresholds are documented in SSLV Sensor Thresholds Document |
deviceSensorTrap (Temperature) | OK = 1 Warning = 10 Critical = 11 | SensorName SensorValue | BLUECOAT-SG-SENSOR-MIB | Not all platform temperature sensors report ‘Warning’ status. Thresholds are documented in SSLV Sensor Thresholds Document |
deviceUsageTrap (CPU, Memory, Disk) | OK = 1 High = 2 | UsageName UsagePercent | BLUECOAT-SG-USAGE-MIB | High = UsagePercent >= 90% |
Trap Name | Defined in MIB | Notes |
nsNotifyShutdown | NET-SNMP-AGENT-MIB | Generated when agent is shutting down |