The "health_cpubsy.swc" script of the swatch command does not show APM in slot 2 on X60 chassis

book

Article ID: 168317

calendar_today

Updated On:

Products

XOS APM

Issue/Introduction

When an APM module is inserted in the slot #2 on the X60 chassis, the module is omitted in the output of the health_cpubsy.swc script of the swatch command

Cause

On the X60 chassis, the slot #2 is a dual purpose slot where NPM and APM modules can operate. There is an issue in the health_cpubsy.swc script which causes that the APM in slot #2 is ignored.

Resolution

This problem will be fixed in XOS 9.6.10, 9.7.6 and 10.0.3.

Workaround

A workaround is to move the APM to any slot number greater than slot #2.