CADT087E UNABLE TO CONTACT SERVER RTC=2F IUCVCODE=00
search cancel

CADT087E UNABLE TO CONTACT SERVER RTC=2F IUCVCODE=00

book

Article ID: 16749

calendar_today

Updated On:

Products

Dynam for VSE Dynam VSE Option

Issue/Introduction

Received a CADT087E UNABLE TO CONTACT SERVER RTC=2F IUCVCODE=00 and a CADT008D Mount message and then the tape job hangs.

What could be the reason and how to avoid it ?

Resolution

The RTC=2F means REQUEST EXPIRED (time out).

This can occur if the operator does not reply to the CADT008D message within 40 Min (40 Minutes is the Default).

To avoid the CADT0087E with RTF=2F, reply to the CADT008D message within the max timeframe.

Additional Information

other RTC Codes and action to solve:

2F REQUEST HAS EXPIRED (TIMED OUT)                                           

1D REQUEST UNSUCCESSFUL   (out of IUCV path)                                                     

1E PATH HAS BEEN SEVERED                                                     

IUCV PATH's empty or IUCV Connection to DYNAMCMS Server was broken (perhaps of IPL VSE).

recommendation: increase OPTION MAXCONN in the CP DIRECTORY for VSE       

restart DYNAMCMS to recreate the IUCV interface.