ProxySG 9000 power supply cage temperature operating range
The table below describes what a normal power supply operating temperature range is, where the warning level starts and where the critical level starts. It also details the actions necessary to help remedy the issue.
System parameter | Operating range | Warning level | System behavior (warning) | Critical level | System behavior (critical) |
Power supply 1 cage temperature | Up to 80C | Above 94C and below 105C | The system management LED is solid amber. The system can operate but it is highly recommended to record the failed component, save the data and shut down the system and call Customer Service. | At or more than 105C | The system management LED starts flashing amber. It is highly recommended to check for the fans and power supply input feed. If both seem OK, shut down the system immediately and call Customer Service. |
Power supply 2 cage temperature | Up to 80C | Above 94C and below 105C | The system management LED is solid amber. The system can operate but it is highly recommended to record the failed component, save the data and shut down the system and call Customer Service. | At or more than 105C | The system management LED starts flashing amber. It is highly recommended to check for the fans and power supply input feed. If both seem OK, shut down the system immediately and call Customer Service. |