DatacomDATACOM - ADCISCOMMON SERVICES FOR Z/OS90S SERVICESDATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OSCOMMON PRODUCT SERVICES COMPONENTCommon ServicesCA ECOMETER SERVER COMPONENT FOCEasytrieve Report Generator for Common ServicesINFOCAI MAINTENANCEIPCUNICENTER JCLCHECK COMMON COMPONENTMainframe VM Product ManagerCHORUS SOFTWARE MANAGERCA ON DEMAND PORTALCA Service Desk Manager - Unified Self ServicePAM CLIENT FOR LINUX ON MAINFRAMEMAINFRAME CONNECTOR FOR LINUX ON MAINFRAMEGRAPHICAL MANAGEMENT INTERFACEWEB ADMINISTRATOR FOR TOP SECRETXpertware
Issue/Introduction
When running a DBUTLTY extract of a table that has compression, why would I get this error?
+PRS012: CANNOT LOAD SPECIFIED RDT/DCT/DICT
How do I resolve this?
Environment
Release: DBCISF00200-15.1-Datacom-Database-Option for CICS Services Component:
Resolution
This error is produced when the compression module is not found in the STEPLIB, JOBLIB or Linklist. Adding the correct loadlib containing the compression module to the jobstep will resolve this error.
Additional Information
As always, please contact CA Technologies support for CA Datacom if you have further questions.