Receiving PRF0879E Not permitted to delete dataset message while extracting data which worked on previous release
search cancel

Receiving PRF0879E Not permitted to delete dataset message while extracting data which worked on previous release

book

Article ID: 16633

calendar_today

Updated On:

Products

Report Facility

Issue/Introduction

Receiving PRF0879E "Not permitted to delete dataset" message while extracting data using Report Facility (PRF).
Was able to complete this on previous release of PRF.

Resolution

On the "Report Facility product controls" screen in the System Profile, the "Dataset Protection?" indicator was enabled (Y) and the Node was set to "1":

1) xxxx.01  r19.0    ----------      TSO  System Profile ----------   12/29 08:50 

    COMMAND==>                                                   USER ID: xxxxxxx  

                       CA Report Facility product controls                         

    Execution Controls...                                                          

      Signon Type:      C   Dataset Protection?    Y Node: 1   Online Printing? Y  

 

..this means that the 1st node of the extract dataset name must match the User ID, which it did not. The USERID above is xxxxxxx, however, the 1st node in the database below is different:

2) xxxx.04  r19.0    -------------- EXTRACT DATASET --------------    12/29 09:03 

    COMMAND==>                                                    xxxxxxx.yyyyyyy 

        EXTRACT TYPE: CSV       QUERY USED FOR EXTRACT: xxxxxxx.yyyyy                 

    -------------------------------------------------------------------  SMS: N    

    Dataset ... 'hlq.EXTRACT(+1)'     Member ....         

.. This indicator was disabled in the prior release. To correct the problem, the Client disabled the indicator again:

Dataset Protection?    N