IDMS CV receives 3969 at startup
search cancel

IDMS CV receives 3969 at startup

book

Article ID: 16615

calendar_today

Updated On:

Products

IDMS IDMS - Database IDMS - ADS

Issue/Introduction



What will cause a U3969 received on an IDMS CV startup with the following messages?

DB347027 V30 DBNAME SYSTEM includes SEGMENTS with conflicting AREA names 

DB347011 V30 Dbname SYSTEM invalid - binding subschema is IDMSNWKA program 

DC391002 V30 BIND RUN UNIT FAILED, SSCSTAT=1494

 

Environment

Release: IDADSO00100-18.5-ADS-for CA-IDMS
Component:

Resolution

The reason for the 3969 is due the fact the SYSTEM DBNAME contains multiple segments with the same area names.

In this case the SYSTEM DBNAME contains both

the CATSYS segment and the SYSSQL segment.

 

It should only include

SEGMENT CATSYS

SEGMENT SYSMSG

SEGMENT SYSTEM

 

Areas

DDLCAT, DDLCATX, DDLCATLOD

DDLDCMSG

DDLDML, DDLDCLOD, DDLDCLOG, DDLDCRUN and DDLDCSCR .